![]() ![]() Moved the gas to Pilot, depressed, got mV up to 500. But after that initial fire it hasn't fired up again.Ĭhecked today, pilot light is still lit. Hayward Control Bezel Assembly for H-Series Electronic ED2 Heater - HAXCPA1932. The burner ran for a few minutes and produced warm water. Voltage dropped to 240 mV, but the burner did fire on. ![]() Yesterday sat down and took some notes as I went through.ġ) Turned the gas valve from Off to PilotĢ) Depressed gas valve and pushed red lighter buttonĤ) Measured the voltage from the millivolt system, jumped from 0 to 540 in about 45s to a minuteĥ) Stopped depressing the gas button for pilot, voltage dropped to 340 mVĦ) Switched from Pilot to On, voltage stayed the sameħ) Flicked the "ON" switch on the front. Toolhome Pool Heater Keypad Membrane Replacement, Pool Heating Control Panel Replace for Hayward Universal H-Series, Fits H100ID1 H150 H150FDN, etc, Black 4.5 out of 5 stars 37 20.99 20. Had some time to work on this again from scratch. So with a new pilot assembly and gas valve I should have a working heater in an old enclosure. The techs told me this thing was old, but the burners are good and the heat exchanger is good. If I called them they'd charge me a usurious rate to look at their broken work. The company that "fixed" it by replacing the parts makes the term incompetent seem like a compliment. I believe this is my issue because 200 mV isn't enough to open the gas valve to fire up the burner.ġ) Should voltage drop once I stop pressing the pilot light button?Ģ) Even though voltage drops it's steady across the TH connections, meaning I think my wiring is good.ģ) What voltage should this thing be at to get the gas valve open? Does it only need to be 500 mV initially?Ĥ) Why would this have worked recently then stopped? Nothing changed except the pilot would shut itself off. Products include a complete line of technologically advanced pumps, filters, heaters, heat pumps, automatic pool cleaners, lighting, controls and salt chlorine generators high quality components that are carefully designed to work together to keep your pool in top condition. The second I let go and the button pops up mV drops down to the 200 range. This is with the gas button pressed down. I can fire up the pilot light and when I measure I can get 522 mV from the pilot generator. I have a multimeter and started to mess with this thing. Walked through the troubleshooting chart and slightly increased pressure and pilot stays lit. My dad has some HVAC experience and mentioned the gas pressure was probably too low. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. I tried to fire it up a few times recently and the pilot light would shut off. Here you’ll gain easy access to information regarding your favorite Hayward products. Then about a month later to bump it up a few degrees, it's been off since then. I used the heater twice, the first time to warm the water from 74 to 84 to get the pool open. Received a new pilot generator assembly and gas valve. It didn't work when we opened the pool, but since we'd lived here less than a year the warranty covered it. Have a 2001 Hayward H200 heater that came with the house. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |